Eutech Instruments 1/2-DIN DO 2000 Oksijen Kontrol Cihazı

Eutech Instruments 1/2-DIN DO 2000 Oksijen Kontrol Cihazı

Advanced features at an economical price!
Programmable for on/off, proportional (P), or proportional integral (PI) control
Adjustable back-lit and UV-protected LCD shows both DO reading and temperature

Four programmable relays with time delay capabilities�two set point relays, one wash relay, and one alarm relay


The DO 2000 combines advanced features and simple set up to provide superior dissolved oxygen control in water treatment and monitoring, galvanic-decontamination, chemical processing, food processing, and neutralization process applications. IP65-rated housing features a large LCD with clear enunciators, alarm status, and operational and error messages. LED indicators allow you to visually monitor transmitter status. Easily access menu-driven programming, calibration, and sensor offsets from the push-button keypad.
P or PI control modes offer pulse length or pulse frequency control. Relays feature a 0 to 2000-second time delay adjustment. Additional features minimize environmental or operational errors and false responses. The housing provides protection against electromagnetic interference. Non-volatile memory keeps set data from being erased due to power failure. Two-level passwords prevent tampering with calibration and set up modes. Built-in calibration checks and compensation for temperature, salinity, and barometric pressure ensure good data. Separately adjustable high and low set-point hysteresis prevent chattering of relays around the set points.

Range mg/L (ppm) 0 to 20
Percent O2 saturation 0 to 200%
Temperature 14 to 257°F
(-10 to 125°C)
Resolution mg/L (ppm) 0.01
Percent O2 saturation 0.1%
Temperature 0.1°C
Accuracy mg/L (ppm) ±1.5% full scale
Percent O2 saturation ±1.5% full scale
Temperature ±0.5°C;
Temp compensation automatic or manual, 14 to 257°F (-10 to 125°C)
Pressure compensation manual input from 555 to 2250 mmHg / 74 to 300 kPa
Salinity compensation manual input from 0.0 to 50.0 ppt
Set point two
Control output Relay 3 SPST relay; maximum 3 A, 250 VAC
Alarm 1 SPDT relay; maximum 3 A, 250 VAC
Current 2 isolated, 0/4 to 20 mA
Voltage 11.5 to 12.5 V
Pulse pulse length (0.5 to 20.0 seconds) or pulse frequency (60 to 120 pulses/min)
Control delay adjustable from 0 to 2000 seconds
Hysteresis adjustable from 0.1 to 1.0 mg/L; 1 to 10%
Password protection Two-level
Display adjustable backlit, dual LCD
Power VAC 80 to 250
Hz 50/60
Dimensions 5-11/16"W x 5-11/16"H x 4-1/4"D (1/2-DIN)