BINDER FP Serisi Materyal Test Kabinleri (FP53, FP115, FP240, FP400, FP720)

BINDER FP Serisi Materyal Test Kabinleri (FP53, FP115, FP240, FP400, FP720)

 

Material test chamber with mechanical convection

A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads.

Advantages:
  • The specialist for demanding heating profiles
  • Adjustable high air exchange rate
  • "Made in Germany" quality

 

Areas of application:
  • Electronics / Semiconductor Industry
  • Plastics Industry
  • Surface Technology

 

FeaturesCustomer benefitsCharacteristics
APT.line™ temperature technology
  • Identical test conditions throughout the chamber interior
  • Independent of specimen size and quantity

APT.line for maximum precision

  • Uniform circulation even under full load
  • Homogeneous temperature conditions throughout test specimens
Performance characteristics
  • Broad range of applications
  • Short warm up times
  • Suitable for numerous industry standards
  • High air exchange rate
  • Adjustable fan speed
  • Large power reserves
  • Temperature range up to 300 °C
Inner chamber concept
  • Maximum occupational safety
  • Easy loading and unloading of specimen material
  • Easy cleaning
  • Inner chamber made of stainless steel
  • Very tight door closure with 2-point door latch
  • Low heat dissipation due to 60 mm insulation
  • Rack with tilt protection
  • No permanent fixtures
Quality
  • Reliable devices with long service lives
  • Short delivery times
  • Minimal maintenance and operating costs
  • Premium quality made in Germany
  • Highly automated series production
  • High-quality materials, state-of-the-art production technology
  • High standard according to DIN 12880 (27-point measurement)
Accessories and Services
  • Flexible solution in terms of size, type and equipment
  • Numerous options for special applications
  • BINDER INDIVIDUAL for customer-specific solutions
  • Worldwide BINDER Service

Comprehensive product portfolio

  • Size 53 to 720 liters
  • Additional product lines: Drying ovens, safety drying ovens, vacuum drying ovens, climate chambers
  • Voltage variants and certificates (UL)
  • Various options: Door with viewing window, access ports, reinforced design for heavy loads, Data Logger Kits
  • Worldwide service network

 

Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results

  • Temperature range from 5 °C above ambient temperature to 300 °C
  • MP controller with 2 programs with 10 sections each, or alternatively 1 program with 20 sections
  • The time of an individual program step can be set to max. 99.59 hours or 999.59 hours. This adjustment applies to all program sections.
    • Integrated weekly program timer with real-time function
    • Adjustable ramp function via program editor
  • Digital temperature setting with an accuracy of one degree
  • Adjustable fan speed
  • Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
  • Elapsed time indicator
  • Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
  • RS 422 interface for use with APT-COM™ DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
  • Units up to 115 liters are stackable
  • 2 chrome-plated racks included
  • BINDER test confirmation
  •  

    FP 53
      Exterior dimensions
    Width (mm) 635
    Height (incl. feet) (mm) 620
    Depth (mm) 575
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 77
    Number of doors (ea.) 1
    Interior dimensions
    Width (mm) 400
    Height (mm) 400
    Depth (mm) 340
    Interior volume (l) 53
    Racks (number standard/max.) 2 / 5
    Load per rack (kg) 15
    Permitted total load (kg) 40
    Weight (empty) (kg) 45
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 2
    at 300 °C (± K) 3,7
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 6
    to 150 °C (min.) 24
    to 250 °C (min.) 45
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 5
    at 300 °C (min.) 10
    Ventilation data
    Ventilation
    at 70 °C (x/h) 59
    at 150 °C (x/h) 64
    at 300 °C (x/h) 53
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230 1N~
    Nominal power (kW) 1,2
    Energy consumption
    at 70 °C (W) 145
    at 150 °C (W) 300
    at 300 °C (W) 720

    1) To 98% of the set value

    FP 115
      Exterior dimensions
    Width (mm) 835
    Height (incl. feet) (mm) 705
    Depth (mm) 645
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 158
    Number of doors (ea.) 1
    Interior dimensions
    Width (mm) 600
    Height (mm) 480
    Depth (mm) 410
    Interior volume (l) 115
    Racks (number standard/max.) 2 / 6
    Load per rack (kg) 20
    Permitted total load (kg) 50
    Weight (empty) (kg) 62
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,7
    at 150 °C (± K) 1,8
    at 300 °C (± K) 3,9
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 7
    to 150 °C (min.) 30
    to 250 °C (min.) 49
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 8
    at 300 °C (min.) 15
    Ventilation data
    Ventilation
    at 70 °C (x/h) 29
    at 150 °C (x/h) 32
    at 300 °C (x/h) 26
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230 1N~
    Nominal power (kW) 1,6
    Energy consumption
    at 70 °C (W) 230
    at 150 °C (W) 544
    at 300 °C (W) 1100

    1) To 98% of the set value

    FP 240
      Exterior dimensions
    Width (mm) 1035
    Height (incl. feet) (mm) 825
    Depth (mm) 745
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 308
    Number of doors (ea.) 2
    Interior dimensions
    Width (mm) 800
    Height (mm) 600
    Depth (mm) 510
    Interior volume (l) 240
    Racks (number standard/max.) 2 / 7
    Load per rack (kg) 30
    Permitted total load (kg) 70
    Weight (empty) (kg) 98
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 2
    at 300 °C (± K) 4,3
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 12
    to 150 °C (min.) 27
    to 250 °C (min.) 50
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 10
    at 300 °C (min.) 16
    Ventilation data
    Ventilation
    at 70 °C (x/h) 19
    at 150 °C (x/h) 20
    at 300 °C (x/h) 18
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230 1N~
    Nominal power (kW) 2,7
    Energy consumption
    at 70 °C (W) 370
    at 150 °C (W) 850
    at 300 °C (W) 1400

    1) To 98% of the set value

    FP 400
      Exterior dimensions
    Width (mm) 1235
    Height (incl. feet) (mm) 1025
    Depth (mm) 765
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 498
    Number of doors (ea.) 2
    Interior dimensions
    Width (mm) 1000
    Height (mm) 800
    Depth (mm) 510
    Interior volume (l) 400
    Racks (number standard/max.) 2 / 10
    Load per rack (kg) 35
    Permitted total load (kg) 90
    Weight (empty) (kg) 145
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 1
    at 150 °C (± K) 2,5
    at 300 °C (± K) 4,8
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 18
    to 150 °C (min.) 35
    to 250 °C (min.) 60
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 17
    at 300 °C (min.) 21
    Ventilation data
    Ventilation
    at 70 °C (x/h) 17
    at 150 °C (x/h) 18
    at 300 °C (x/h) 16
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 400 3N~
    Nominal power (kW) 3,4
    Energy consumption
    at 70 °C (W) 520
    at 150 °C (W) 1200
    at 300 °C (W) 2340

    1) To 98% of the set value

    FP 720
      Exterior dimensions
    Width (mm) 1235
    Height (incl. casters) (mm) 1530
    Depth (mm) 865
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 869
    Number of doors (ea.) 2
    Interior dimensions
    Width (mm) 1000
    Height (mm) 1200
    Depth (mm) 610
    Interior volume (l) 720
    Racks (number standard/max.) 2 / 15
    Load per rack (kg) 45
    Permitted total load (kg) 120
    Weight (empty) (kg) 184
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 1
    at 150 °C (± K) 2
    at 300 °C (± K) 5,5
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 25
    to 150 °C (min.) 39
    to 250 °C (min.) 65
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 20
    at 300 °C (min.) 24
    Ventilation data
    Ventilation
    at 70 °C (x/h) 11
    at 150 °C (x/h) 12
    at 300 °C (x/h) 10
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 400 3N~
    Nominal power (kW) 5
    Energy consumption
    at 70 °C (W) 570
    at 150 °C (W) 1320
    at 300 °C (W) 2600

    1) To 98% of the set value

     

    « Materyal Test Kabinleri