BINDER FED Serisi Mechanical Convection Etüvler ( FED53, FED115, FED240, FED400, FED720 )

BINDER FED Serisi Mechanical Convection Etüvler ( FED53, FED115, FED240, FED400, FED720 )

 

Heating chamber with mechanical convection

The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly adaptable. With advanced timing functions and a digitally controllable fan, this heating chamber easily controls temperature and convection conditions.

Advantages:
  • Fast, even tempering
  • Wide temperature range
  • Quality "Made in Germany"

 

Areas of application:
  • Electronics / Semiconductor Industry
  • Basic Research / Research Institutes
  • Plastics Industry

 

FeaturesCustomer benefitsCharacteristics
APT.line™
  • Quick drying
  • Identical test conditions throughout the chamber interior
  • Independent of specimen size and quantity

APT.line™ for maximum precision

  • Uniform circulation even under full load
  • Homogeneous temperature conditions throughout specimen material
Temperature range
  • Broad range of applications
  • Short warm up times

Standard up to 300 °C

  • Large power reserves
Inner chamber concept
  • Maximum occupational safety
  • Easy loading and unloading of specimen material
  • Easy cleaning

Inner chamber made of stainless steel

  • Very tight door closure with 2-point door latch
  • Low heat dissipation due to 60 mm insulation
  • Rack with tilt protection
  • No permanent fixtures
Standard equipment
  • Reliable, easy handling

Comprehensive standards

  • Microprocessor control
  • Ergonomically positioned controller.
  • RS 422 interface
  • PT 100 temperature sensor
Quality
  • Reliable devices with long service lives
  • Short delivery times
  • Minimal maintenance and operating costs

Premium quality

  • Highly automated
  • Series production
  • High-quality materials, state-of-the-art production technology
  • High standard according to DIN 12880 (27-point measurement)
Accessories and Services
  • Flexible solution in terms of size, type and equipment
  • Optimal solution for numerous applications
  • BINDER INDIVIDUAL for customer-specific solutions
  • Worldwide BINDER Service

Comprehensive product portfolio

  • Size 53 to 720 liters
  • Additional product lines with humidity, light, CO2 or vacuum
  • Voltage variants (UL) and certificates
  • Various options: Door with viewing window, access ports, reinforced shelves, Data Logger Kits
  • Worldwide service network
APT.line™
  • Quick drying
  • Identical test conditions throughout the chamber interior
  • Independent of specimen size and quantity

APT.line™ for maximum precision

  • Uniform circulation even under full load
  • Homogeneous temperature conditions throughout specimen material
Temperature range
  • Broad range of applications
  • Short warm up times

Standard up to 300 °C

  • Large power reserves
Inner chamber concept
  • Maximum occupational safety
  • Easy loading and unloading of specimen material
  • Easy cleaning

Inner chamber made of stainless steel

  • Very tight door closure with 2-point door latch
  • Low heat dissipation due to 60 mm insulation
  • Rack with tilt protection
  • No permanent fixtures
Standard equipment
  • Reliable, easy handling

Comprehensive standards

  • Microprocessor control
  • Ergonomically positioned controller.
  • RS 422 interface
  • PT 100 temperature sensor
Quality
  • Reliable devices with long service lives
  • Short delivery times
  • Minimal maintenance and operating costs

Premium quality

  • Highly automated
  • Series production
  • High-quality materials, state-of-the-art production technology
  • High standard according to DIN 12880 (27-point measurement)
Accessories and Services
  • Flexible solution in terms of size, type and equipment
  • Optimal solution for numerous applications
  • BINDER INDIVIDUAL for customer-specific solutions
  • Worldwide BINDER Service

Comprehensive product portfolio

  • Size 53 to 720 liters
  • Additional product lines with humidity, light, CO2 or vacuum
  • Voltage variants (UL) and certificates
  • Various options: Door with viewing window, access ports, reinforced shelves, Data Logger Kits
  • Worldwide service network

Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results

  • Temperature range from 5 °C above ambient temperature to 300 °C
  • MS controller with several timer functions
  • Controller timer functions: delayed ON, delayed OFF, temperature dependent delayed OFF
    • Digital temperature setting with an accuracy of one degree
  • Adjustable fan speed
  • Front ventilation flap slide and rear exhaust duct Ø 50 mm (1.97 inch)
  • Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
  • RS 422 interface for use with APT-COM™ DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
  • Units up to 115 liters are stackable
  • 2 chrome-plated racks included
  • BINDER test confirmation
  •  

    FED 53
    Exterior dimensions
    Width (mm) 635
    Height (incl. feet) (mm) 620
    Depth (mm) 575
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 77
    Number of doors (ea.) 1
    Interior dimensions
    Width (mm) 400
    Height (mm) 400
    Depth (mm) 330
    Interior volume (l) 53
    Racks (number standard/max.) 2 / 5
    Load per rack (kg) 15
    Permitted total load (kg) 40
    Weight (empty) (kg) 44
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 2
    at 300 °C (± K) 3,7
    Temperature fluctuation at 70 °C (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 6
    to 150 °C (min.) 24
    to 250 °C (min.) 45
    to 300 °C (min.) 55
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 5
    at 300 °C (min.) 10
    Ventilation data
    Ventilation
    at 150 °C (x/h) 43
    at 300 °C (x/h) 66
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230
    Nominal power (kW) 1,2
    at 70 °C (W) 162
    at 150 °C (W) 397
    at 300 °C (W) 933

    1) To 98% of the set value

     

     

    FED 115
    Exterior dimensions
    Width (mm) 835
    Height (incl. feet) (mm) 705
    Depth (mm) 645
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 158
    Number of doors (ea.) 1
    Interior dimensions
    Width (mm) 600
    Height (mm) 480
    Depth (mm) 400
    Interior volume (l) 115
    Racks (number standard/max.) 2 / 6
    Load per rack (kg) 20
    Permitted total load (kg) 50
    Weight (empty) (kg) 62
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,7
    at 150 °C (± K) 1,8
    at 300 °C (± K) 3,9
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 7
    to 150 °C (min.) 30
    to 250 °C (min.) 49
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 8
    at 300 °C (min.) 15
    Ventilation data
    Ventilation
    at 70 °C (x/h) 29
    at 150 °C (x/h) 32
    at 300 °C (x/h) 26
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230
    Nominal power (kW) 1,6
    Energy consumption
    at 70 °C (W) 230
    at 150 °C (W) 544
    at 300 °C (W) 1100

    1) To 98% of the set value

     

     

    FED 240
    Exterior dimensions
    Width (mm) 1035
    Height (incl. feet) (mm) 825
    Depth (mm) 745
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 308
    Number of doors (ea.) 2
    Interior dimensions
    Width (mm) 800
    Height (mm) 600
    Depth (mm) 500
    Interior volume (l) 240
    Racks (number standard/max.) 2 / 7
    Load per rack (kg) 30
    Permitted total load (kg) 70
    Weight (empty) (kg) 96
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 2
    at 300 °C (± K) 4,3
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 12
    to 150 °C (min.) 27
    to 250 °C (min.) 50
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 10
    at 300 °C (min.) 16
    Ventilation data
    Ventilation
    at 70 °C (x/h) 19
    at 150 °C (x/h) 20
    at 300 °C (x/h) 18
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230
    Nominal power (kW) 2,7
    Energy consumption
    at 70 °C (W) 370
    at 150 °C (W) 850
    at 300 °C (W) 1400

    1) To 98% of the set value

     

     

    FED 400
    Exterior dimensions
    Width (mm) 1235
    Height (incl. feet) (mm) 1025
    Depth (mm) 765
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 498
    Number of doors (ea.) 2
    Interior dimensions
    Width (mm) 1000
    Height (mm) 800
    Depth (mm) 500
    Interior volume (l) 400
    Racks (number standard/max.) 2 / 10
    Load per rack (kg) 35
    Permitted total load (kg) 90
    Weight (empty) (kg) 145
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 1
    at 150 °C (± K) 2,5
    at 300 °C (± K) 4,8
    Temperature fluctuation at 70 °C (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 18
    to 150 °C (min.) 35
    to 250 °C (min.) 60
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 17
    at 300 °C (min.) 21
    Ventilation data
    Ventilation
    at 70 °C (x/h) 17
    at 150 °C (x/h) 18
    at 300 °C (x/h) 16
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 400 3N~
    Nominal power (kW) 3,4
    Energy consumption
    at 70 °C (W) 520
    at 150 °C (W) 1200
    at 300 °C (W) 2340

    1) To 98% of the set value

     

    FED 720
      Exterior dimensions  
      Width (mm) 1235
      Height (incl. castors) (mm) 1530
      Depth (mm) 865
      Plus door handle and connection (mm) 105
      Wall clearance, rear (mm) 100
      Wall clearance, side (mm) 160
      Exhaust duct (outer Ø mm) 52
      Steam space volume (l) 869
      Number of doors (ea.) 2
         
      Interior dimensions  
      Width (mm) 1000
      Height (mm) 1200
      Depth (mm) 600
      Interior volume (l) 720
      Racks (number standard/max.) 2 / 15
      Load per rack (kg) 45
      Permitted total load (kg) 120
      Weight (empty) (kg) 195
         
      Temperature data  
      Temperature range approx. 5 °C above ambient temperature to (°C) 300
      Temperature variation  
      at 70 °C (± K) 1
      at 150 °C (± K) 2
      at 300 °C (± K) 5,5
      Temperature fluctuation at 70 °C (± K) 0,3
      Warm-up time 1)  
      to 70 °C (min.) 25
      to 150 °C (min.) 39
      to 250 °C (min.) 65
      Recovery time after doors were open for 30 sec. 1)  
      at 70 °C (min.) 2
      at 150 °C (min.) 20
      at 300 °C (min.) 24
         
      Ventilation data  
      Ventilation  
      at 70 °C (x/h) 11
      at 150 °C (x/h) 12
      at 300 °C (x/h) 10
         
      Electrical data  
      IP protection class acc. to EN 60529 IP 20
      Voltage (± 10%) 50 / 60 Hz (V) 400 3N~
      Nominal power (kW) 5
      Energy consumption  
      at 70 °C (W) 570
      at 150 °C (W) 1320
      at 300 °C (W) 2600

    1) To 98% of the set value

     

     

    « Etüvler