BINDER FD Serisi Mechanical Convection Etüvler (FD23, FD53, FD115, FD240 )

BINDER FD Serisi Mechanical Convection Etüvler (FD23, FD53, FD115, FD240 )

 

Heating oven with mechanical convection

A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous temperature distribution, quick dynamics and powerful fan, this heating oven saves valuable time. 

 

 

Advantages:
  • Fast, even tempering
  • Wide temperature range
  • Quality "Made in Germany"

 

Areas of application:
  • Electronics / Semiconductor Industry
  • Basic Research / Research Institutes
  • Plastics Industry

 

FeaturesCustomer benefitsCharacteristics
APT.line™
  • Quick drying
  • Identical test conditions throughout the chamber interior
  • Independent of specimen size and quantity

APT.line™ for maximum precision

  • Uniform circulation even under full load
  • Homogeneous temperature conditions throughout specimen material
Temperature range
  • Broad range of applications
  • Short warm up times

Standard up to 300 °C

  • Large power reserves
Inner chamber concept
  • Maximum occupational safety
  • Easy loading and unloading of specimen material
  • Easy cleaning

Inner chamber made of stainless steel

  • Very tight door closure with 2-point door latch
  • Low heat dissipation due to 60 mm insulation
  • Rack with tilt protection
  • No permanent fixtures
Standard equipment
  • Reliable, easy handling

Comprehensive standards

  • Microprocessor control
  • Ergonomically positioned controller.
  • PT 100 temperature sensor
Quality
  • Reliable devices with long service lives
  • Short delivery times
  • Minimal maintenance and operating costs

Premium quality

  • Highly automated
  • Series production
  • High-quality materials, state-of-the-art production technology
  • High standard according to DIN 12880 (27-point measurement)
Accessories and Services
  • Flexible solution in terms of size, type and equipment
  • Optimal solution for numerous applications
  • BINDER INDIVIDUAL for customer-specific solutions
  • Worldwide BINDER Service

Comprehensive product portfolio

  • Size 23 to 240 liters
  • Additional product lines with humidity, light, CO2 or vacuum
  • Voltage variants (UL) and certificates
  • Various options: Door with viewing window, access ports, reinforced shelves, Data Logger Kits
  • Worldwide service network

 

 

Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results

  • Temperature range from 5 °C above ambient temperature to 300 °C
  • DS control with integrated timer 0 to 99,59 hrs
  • Digital temperature setting with an accuracy of one degree
  • Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
  • Adjustable front ventilation flap slide and rear exhaust Ø 50 mm (1.97 inch)
  • Units up to 115 liters are stackable
  • 2 chrome-plated racks included
  • FD 23 with space-saving door mechanism
  • BINDER test confirmation
  •  

    FD 23
      Exterior dimensions
    Width (mm) 435
    Height (incl. feet) (mm) 495
    Depth (mm) 520
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 100
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 36
    Number of doors (ea.) 1
    Interior dimensions
    Width (mm) 222
    Height (mm) 330
    Depth (mm) 300
    Interior volume (l) 20
    Racks (number standard/max.) 2 / 3
    Load per rack (kg) 12
    Permitted total load (kg) 25
    Weight (empty) (kg) 33
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 2,2
    at 300 °C (± K) 4,3
    Temperature fluctuation at 70 °C (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 7
    to 150 °C (min.) 22
    to 300 °C (min.) 45
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 4
    at 300 °C (min.) 9
    Ventilation data
    Ventilation
    at 70 °C (x/h) 59
    at 150 °C (x/h) 64
    at 300 °C (x/h) 53
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230
    Nominal power (kW) 0,8
    Energy consumption
    at 70 °C (W) 145
    at 150 °C (W) 300
    at 300 °C (W) 720

    1) To 98% of the set value

     

     

    FD 53
      Exterior dimensions
    Width (mm) 635
    Height (incl. feet) (mm) 620
    Depth (mm) 575
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 77
    Number of doors (ea.) 1
    Interior dimensions
    Width (mm) 400
    Height (mm) 400
    Depth (mm) 340
    Interior volume (l) 53
    Racks (number standard/max.) 2 / 5
    Load per rack (kg) 15
    Permitted total load (kg) 40
    Weight (empty) (kg) 44
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 2
    at 300 °C (± K) 3,7
    Temperature fluctuation at 70 °C (± K) 0,3
    Heating up time 1)
    to 70 °C (min.) 7
    to 150 °C (min.) 24
    to 300 °C (min.) 60
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 5
    at 300 °C (min.) 9
    Ventilation data
    Ventilation
    at 70 °C (x/h) 59
    at 150 °C (x/h) 64
    at 300 °C (x/h) 53
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50/60 Hz (V) 230
    Nominal power (kW) 1,2
    Energy consumption
    at 70 °C (W) 172
    at 150 °C (W) 429
    at 300 °C (W) 951

    1) To 98% of the set value

     

     

    FD 115
      Exterior dimensions
    Width (mm) 835
    Height (incl. feet) (mm) 705
    Depth (mm) 645
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 158
    Number of doors (ea.) 1
    Interior dimensions
    Width (mm) 600
    Height (mm) 480
    Depth (mm) 410
    Interior volume (l) 115
    Racks (number standard/max.) 2 / 6
    Load per rack (kg) 20
    Permitted total load (kg) 50
    Weight (empty) (kg) 62
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 1,8
    at 300 °C (± K) 3,9
    Temperature fluctuation (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 7
    to 150 °C (min.) 28
    to 300 °C (min.) 49
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 5
    at 300 °C (min.) 12
    Ventilation data
    Ventilation
    at 70 °C (x/h) 29
    at 150 °C (x/h) 32
    at 300 °C (x/h) 26
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230
    Nominal power (kW) 1,6
    Energy consumption
    at 70 °C (W) 230
    at 150 °C (W) 544
    at 300 °C (W) 1100

    1) To 98% of the set value

     

     

    FD 240
      Exterior dimensions
    Width (mm) 1035
    Height (incl. feet) (mm) 825
    Depth (mm) 745
    Plus door handle and connection (mm) 105
    Wall clearance, rear (mm) 100
    Wall clearance, side (mm) 160
    Exhaust duct (outer Ø mm) 52
    Steam space volume (l) 308
    Number of doors (ea.) 2
    Interior dimensions
    Width (mm) 800
    Height (mm) 600
    Depth (mm) 510
    Interior volume (l) 240
    Racks (number standard/max.) 2 / 7
    Load per rack (kg) 30
    Permitted total load (kg) 70
    Weight (empty) (kg) 96
    Temperature data
    Temperature range approx. 5 °C above ambient temperature to (°C) 300
    Temperature variation
    at 70 °C (± K) 0,8
    at 150 °C (± K) 2
    at 300 °C (± K) 4,3
    Temperature fluctuation at 70 °C (± K) 0,3
    Warm-up time 1)
    to 70 °C (min.) 11
    to 150 °C (min.) 24
    to 300 °C (min.) 50
    Recovery time after doors were open for 30 sec. 1)
    at 70 °C (min.) 2
    at 150 °C (min.) 6
    at 300 °C (min.) 13
    Ventilation data
    Ventilation 20
    at 70 °C (x/h) 19
    at 150 °C (x/h) 20
    at 300 °C (x/h) 18
    Electrical data
    IP protection class acc. to EN 60529 IP 20
    Voltage (± 10%) 50 / 60 Hz (V) 230
    Nominal power (kW) 2,7
    Energy consumption
    at 70 °C (W) 370
    at 150 °C (W) 850
    at 300 °C (W) 1400

    1) To 98% of the set value 

     

     

    OPTIONS
    Access ports with silicone plug, 10, 30, 50, 100 mm O
    Anti-slip rubber pads (1 set of 4 pieces) for safe stacking (not possible for FD 23) O
    Independent adjustable temperature safety device class 3.1 (DIN 12880) with optical alarm O
    Analog temperature output, 4 - 20 mA with 6-pin DIN socket (output not adjustable) O
    Over temperature alarm, audible, can be switched off. Temperature limit can be set at the independent, adjustable temperature safety device O
    Securing elements for additional fastening of racks (1 set of 4 pieces) O
    Temperature measurement acc. to DIN 12880 at 150 °C or at specified testing temperature with measuring protocol and certificate O
    Factory calibration certificate. Measurement in center of chamber at 150 °C (302 °F) or at specified testing temperature O
    Extension to factory calibration certificate. Each additional measurement at additional measuring point or temperature O
    Data Logger Kit T 350: For continuous temperature recording of 0 °C to 350 °C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for mounting to the BINDER unit O
    Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable O
    Rack, chrome-plated O
    Rack, stainless steel O
    Shelf, perforated, stainless steel O
    Locking door handle with key O
    Door gasket, FKM (Viton) O
    Door with window 180 x 180 mm and interior lighting (15 W) O

    « Etüvler