BINDER CB210 CO2 İnkübatör

BINDER CB210 CO2 İnkübatör

 

CO2 incubator with additional process controls

The BINDER CB series CO2 incubator is the premium class among the CO2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CO2 incubator of the CB series is up to even complex cultivation experiments or individual environments.

 

cb210 

 

Advantages:
  • Hot air sterilization at 180 °C
  • Seamless, deep-drawn inner chamber made of stainless steel
  • Unique BINDER technology (patented air jacket system, controlled condensation, etc.)

 

Areas of application:
  • Bio Tissue Engineering
  • In vitro Fertilization (IVF)
  • Clinics / University Hospitals

 

FeaturesCustomer benefitsCharacteristics
Sterilization
  • Complete elimination of bacteria, spores, etc.
  • Reliable sterilization of the atmosphere and all surfaces
  • Minimal sterilization costs

180 °C hot air sterilization

  • Standards compliance, meets all relevant standards
  • Automatic sterilization process
Permadry™ humidity system
  • Uniform osmotic cell pressure
  • Optimum cell growth even with microwell plates
  • No Provides no sources of contamination.

Controlled humidification system

  • Defined recondensation point
  • Dry interior walls
  • High humidity
  • Rapid humidity recovery times
  • Simple water exchange through water pan
APT.line™ heating technology
  • Optimal, uniform cell growth throughout the inner chamber

Preheating chamber with VENTAIR™ air jacket

  • Homogeneous temperature distribution
  • Rapid recovery after temperature drop
  • Accurate temperature control
Gas distribution
  • Stable pH value

Gas mixing head with venturi effect

  • Homogeneous CO2 distribution
  • Fast effective aeration
Inner chamber concept
  • Easy cleaning
  • Fully usable volume 53, 150, 210 l
  • No Provides no sources of contamination.

Seamless, deep-drawn inner chamber

  • Integrated shelf support system
  • Burr-free stainless steel perforated sheets with tilt protection
CO2 measurement
  • Stable pH value even with frequent door opening
  • Long-term stable system
  • Low maintenance costs

Single-beam infrared sensor

  • Rapid response time
  • Measures CO2 in real-time
  • Independent of gas and humidity
Operating costs
  • Minimal operating costs
  • Time savings
  • Minimal work and material costs for sterilization

 

Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and best cell growth

  • Temperature range from 7 °C above ambient temperature to 60 °C
  • MCS controller for temperature and CO2 concentration
  • User-friendly LCD screen
    • Easy-to-read menu guide
    • Integrated electronic chart recorder
    • Variety of options for the graphic display of process parameters
    • Real time clock
  • Standard-compliant hot air sterilization at 180 °C (DIN 58947)
  • VENTAIR™ Jacket System
  • Drift-free infrared CO2 measurement system
  • Patended Gas mixing nozzle
  • Permadry System - condensation-free double-pan humidification system, maintains dry interior walls
  • Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges)
  • Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring
  • Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
  • Tightly-fitted inner glass door
  • RS 422 interface for communication software APT-COM™ DataControlSystem
  • 2 perforated stainless steel shelves with standard equipement and O2 control
  • Units are stackable with stacking adapter
  • Door lock
  • BINDER test confirmation
  •  

    CB 210
      Exterior dimensions  
      Width (mm) 740
      Height (incl. feet) (mm) 1070
      Depth (plus 54 mm for door handle and connection) (mm) 715
      Wall clearance side / rear (mm) 50 / 100
      Number of doors (ea.) 1
      Inner glass door(s) 1
         
      Interior dimensions  
      Width (mm) 560
      Height (mm) 750
      Depth (mm) 500
      Interior volume (l) 210
      Stainless steel shelf (number standard/max.) 3 / 8
      Dimensions of shelf, width x depth (mm) 555,5 x 444
      Load per shelf (kg) 10
      Permitted total load (kg) 30
      Weight (empty) (kg) 121
         
      Temperature data  
      Temperature range approx. 7 °C above ambient temperature to (°C) 60
      Temperature variation at 37 °C (± K) 0,4
      Temperature fluctuation (± K) 0,1
      Recovery time after door was opened for 30 sec. at 37 °C (min) 1) 3
         
      Humidity data  
      Humidity (±2% r.h.) 95
         
      CO2 data  
      CO2 range (% CO2) 0-20
      Setting accuracy (Vol.-% CO2) 0,1
      Recovery time after door was opened for 30 sec. at 5 vol. % (min.) 1) 9
      CO2 measurement IR
      Connection hose nozzle for CO2 DN 6 for hose with internal diameter (mm) 6
         
      O2 data  
      O2 range (Vol.-% O2) 0,2 - 95
      Setting accuracy (Vol.-% O2) 0,1
      Recovery time after door was opened for 30 sec. (min.) 1)  
      at 1.0 vol. % O2 (min.) 54
      at 5.0 vol. % O2 (min.) 11
      O2 measurement ZrO2
      Gas connection hose nozzle for O2 / N2 DN 6 for hose with internal diameter (mm) 6
         
      Electrical data  
      Voltage (± 10%) 50 / 60 Hz (V) 230
      Nominal power (kW) 1,5
      Energy consumption at 37 °C (W) 2) 130

    1) up to 98 % of the set value
    2) These values can be used for dimensioning air condition systems.

     

    OPTIONS
    Silicone access port with two silicone plugs, 30 mm, left side O
    Silicone access port with two silicone plugs, 30 mm, right side O
    Silicone access port with two silicone plugs, 30 mm, back O
    Lockable controller keyboard O
    Gas tank connection set for CO2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose O
    Gas tank connection set for O2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose O
    Gas tank connection set for N2 consisting of a gas tank pressure regulator max. pressure 10 bar) with connection parts and 5 m hose O
    BINDER Gas Supply Service external gas tank replacement for connecting 2 gas tanks, either CO2 or N2, with audible and visual alarms, as well as potential-free alarm output O
    Unit conversion from RS 422 to Ethernet interface O
    4 - 20 mA analog outputs for temperature and CO2 measurements (e.g. chart recorder connection) with 6-pin DIN socket (output not adjustable). O
    Switched LEMO inner chamber socket (coverable) and LEMO connector (max. current carrying capacity 230 V AC - 3 A) (protection class IP 65) O
    Independent Intelligent Fail Safe monitoring function. Unique safety function used to prevent unnoticed deviations of the CO2 concentration from the set value. Note: Not possible in conjunction with access ports or divided inner glass door O
    Calibration certificate for temperature and CO2 (temperature measurement in center / CO2 measurement performed using analyzed test gas at 37 °C and 5% CO2) O
    Calibration certificate for optional O2 control, O2 measurement with analyzed test gas 1% O2 O
    Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C or at specified temperature with measuring protocol and certificate O
    Manual for Primary Human Cell Culture, in English O
    Current feedthrough (8-pin) for low voltage with LEMO socket (pluggable) and LEMO plug O
    Internal CO2 tank changer for connecting 2 gas tanks. Precise control over the current condition of CO2 supply to incubator by means of alarm messaging and incident reporting O
    Internal CO2 tank changer for connecting 2 gas tanks with external connection for up to one additional CO2 incubator. Precise control over the current condition of CO2 supply to incubator by means of alarm messaging and incident reporting O
    Internal O2 and N2 tank changer for connecting 2 gas tanks each O
    Perforated shelf, stainless steel O
    Divided shelf (1 shelf level) for gas-tight divided inner glass door, stainless steel O
    Base on casters O
    Stable vibration-free stacking frame on casters with stop brake for direct and safe stacking of two units of the CB 210 series with locking device O
    Stacking adapter CB for direct thermal decoupled stacking of two units of the CB 210 series O
    CELLROLL Set, modular and expandable roller bottle system for cell cultivation, 6 roller bottles O

     

     

    « İnkübatörler