- Industrial
- Automatic Paper Testing ( Autoline Profiler )
- Color Measurement Instruments
- Electro Analyzer
- Gas Analyzers
- Industrial Textile Treating Systems
- On-Line Chemical Analyzers
- Package Quality Testing Instruments
- Paper & Board Process Optimization Instruments
- Paper Testing Instruments
- Petroleum Testing Instruments
- Pulp Testing Instruments
- Sieve Shakers / Sieves
- Laboratory
- Amino Acid Analyzers
- Autoclaves
- Balances
- Baths and Circulators
- Bio Reactors / Fermentors
- Blenders
- Block Heaters
- Calibration Equipment
- Calorimeters
- Centrifuges
- Chromatography
- Conductivity Meters
- Deep Freezers / Freezers
- Electrical Test Equipment
- Electronic Test Instruments
- Electrophoresis and Accessories
- Flowmeters
- Fraction Collectors
- Furnaces
- Glassware Washers
- Heating Mantles
- Homogenizers
- Hot Plates
- Incubators
- Ion Meters
- Liyofilization (Freeze Drying) Instruments
- Magnetic Stirrers
- Melting Point Apparatus
- Microplate Readers
- Microscopes
- Mills
- Mixers
- Moisture Analyzers
- Organic Synthesis Systems
- Ovens
- Oxygen Meters
- pH Meters
- Photometers
- Polorimeters
- Presses
- Pressure / Vacuum Meters
- Pumps
- Reactors
- Recorder and Dataloggers
- Refractometers
- Rotary Evaporators
- Salinity Meters
- Sample Preparation Bombs
- Shakers
- Spectrophotometers
- Sterilizers
- Temperature Controlled Heating & Cooling Systems
- Temperature Measuring Instruments
- Thermocycler (PCR)
- Thermohygrometers
- Ultrasonic Cleaners
- Vibration / Leak Detection Instruments
- Viscometers
- Water Purification Systems
- Water Testing Instruments
Series 4520 1 and 2 Liter Bench Top Reactors
Series 4520 1 and 2 Liter Bench Top Reactors
These are the largest of the Parr Reactors that can be handled on a bench top. They can be furnished with either a self-sealing, O-ring closure for working temperatures up to 225 °C or with a flat, PTFE gasket for higher temperatures to 350 °C. Both fixed head and moveable vessel designs are available. It should be noted, however, that the 2 liter, fixed head model is tall and may not be convenient to operate on a standard height bench top. We recommend using a floor stand. (See Series 4530)
(Shown at Left) Model 4525 Reactor, 1000 mL, Moveable Vessel, and 4843 Controller.
With their larger diameter, these mid-size reactors have sufficient space for special modifications, such as: an internal cooling coil, a bottom drain valve, a ball valve for a solids charging port, catalyst addition devices, condensers, electrical feed-through’s and more. Details are provided in the Options Section.
« Reactors
Series 4520 1 and 2 Liter Bench Top Reactors
These are the largest of the Parr Reactors that can be handled on a bench top. They can be furnished with either a self-sealing, O-ring closure for working temperatures up to 225 °C or with a flat, PTFE gasket for higher temperatures to 350 °C. Both fixed head and moveable vessel designs are available. It should be noted, however, that the 2 liter, fixed head model is tall and may not be convenient to operate on a standard height bench top. We recommend using a floor stand. (See Series 4530)(Shown at Left) Model 4525 Reactor, 1000 mL, Moveable Vessel, and 4843 Controller.
With their larger diameter, these mid-size reactors have sufficient space for special modifications, such as: an internal cooling coil, a bottom drain valve, a ball valve for a solids charging port, catalyst addition devices, condensers, electrical feed-through’s and more. Details are provided in the Options Section.
The standard stirrer drive on these 4520 Models works well for reaction mixtures with viscosity up to 25,000 centipoise. For heavier stirring loads, these reactors can be equipped with larger magnetic drives, more powerful motors and drive trains capable of delivering additional stirring torque.
Model 4642 Stirred Vessel Assembly,
2000 mL
Series 4520 Reactor Specifications
| Shading indicates specifications that change within models |
| Model Number | 4523 | 4524 | 4525 | 4526 |
| Sizes, mL | 1000 | 2000 | 1000 | 2000 |
| Maximum Pressure | 1900 psi (130bar) | |||
| Maximum Temperature | ||||
| with FKM 0-ring | 225 °C | |||
| with FFKM 0-ring | 275 °C | |||
| with PTFE Flat Gasket | 350 °C | |||
| Vessel Style | Fixed Head | Moveable | ||
| Reactor Mounting | Bench Top or Floor Stand | |||
| Closure (Cap Screws) | Split-Ring (6) | |||
| Valve Connections | 1/8" Male NPT | |||
| Magnetic Stirrer, Model No. | A1120HC6 | |||
| Maximum Torque | 16 Inch-Pounds | |||
| Impeller(s), 6-blade | 2 | |||
| Pressure Gage, Size | 4.5 inches | |||
| Range | 0-2000 psi (140 bar)* | |||
| Temperature Measurement | Thermowell | |||
| Cooling Coil | Optional | |||
| Style | Serpentine or Spiral | |||
| Bottom Drain Valve | A465VB, 3/8" NPT | |||
| Heater Style | Calrod | |||
| Heater Power Watts | 1000 | 1500 | 1000 | 1500 |
| Stirrer Motor | 1/8 hp variable speed* | |||
| Electrical Supply | ||||
| Volts | 115 or 230 | |||
| Maximum Load | 14/7 amps* | |||
| Vessel Dimensions | ||||
| Inside Diameter, inches | 4.0 | |||
| Inside Depth,inches | 5.4 | 10.5 | 5.4 | 10.5 |
| Weight of Vessel, pounds | 28 | 32 | 32 | 36 |
| Reactor Dimensions | ||||
| Width, inches w/o Controller | 16.5 | 16.5 | ||
| Depth, inches | 23.5 | 23.5 | ||
| Height, inches | 36 | 48 | 36 | 48 |
| Weight, pounds | 125 | 130 | 120 | 125 |
| Spare Parts Kit | 4509M | |||
*Other options available. See Options Section and Ordering Guide
Series 4520 Ordering Guide
A composite indentification number to be used when ordering a 4520 Series Reactor can be developed by combining individual symbols from the separate sections.
Example
A 2000 mL, T316SS, reactor with fixed head, general purpose magnetic drive, PTFE gasket, 115V 50/60Hz explosion-proof 1/4 hp motor, 2000 psi gage and programable controller with pressure display module would be listed as:
| No. 4524-T-GP-SS-115-XP.25-2000-4843-PDM Model Gasket Stirrer Material Voltage Motor No.4524 -T -GP -SS -115 -XP.25 -etc.... A B C D E F
|