RAYPA Benchtop Sterilization Autoclaves

RAYPA Benchtop Sterilization Autoclaves

 o4

  CONSTRUCTION
  • Sterilisation chamber made of stainless steel AISI 316 polished and bright
  • Exterior case in stainless steel, lid and control panel support oven painted

SAFETY SYSTEMS

  • Safety device that blocks the program if the door is not correctly closed. The same device aborts the sterilisation cycle and removes the autoclave’s pressure automatically, when trying to open the door while the sterilisation cycle is on.
  • SAFETY VALVE, removes the inner pressure in case of going over the levels
  • SAFETY THERMOSTAT, disconnects the autoclave’s heating in case of overtemperature.

WORKING CYCLES

  • The autoclave “CLINOCLAV-M” is equipped with 5 sterilisation programmes for a fast and perfect treatment of the different materials, making the user’s work easy.
   
         
     
        CONTROL PANNEL
  1. LCD SCREEN
    It informs about the sterilisation process and about the different sequences or malfunctions of the named process.
  2. QUICK STERILISATION
    Temperature: 134°C.
    Time: 3 min.
    WITHOUT DRYING INDICATED FOR:
    Turbines, counter-angles, hand-pieces, glass and non-packed instruments
  3. STERILISATION IN GENERAL
    Temperature: 134°C.
    Time: 15 min.
    Drying: 12 min.
    INDICATED FOR:
    Pourous materials (gauzes, fabrics...)
    Bagged instrumental, instrumental in general
  4. DELICATE INSTRUMENTAL
    Temperature: 121°C.
    Time: 30 min.
    Drying: 12 min.
    INDICATED FOR:
    Manufactured materials in plastic, wired and conductions, ultrasonic hand-pieces, electroscalpels,...
  5. OPTIONAL FLASH
    Program adjustable to the demmands of the user for the sterilisation. It allows the introduction of temperature and time at your own choice, so the CLINOCLAV-M will adapt to the requirements that in the future will be compulsory by law.
  6. DISINFECTION
    Temperature: 105°C.
    Time: 30 min.
    Drying: 12 min.
    INDICATED FOR:
    Packed or unpacked material (optic fiber, polymeration lamp-heads,...)
  7. PRINTER KEY ON/OFF
    Key to print the data of the last cycle.
  8. START/STOP KEY
    Key to start or to stop the sterilisation program programmed.
  9. PRESSURE AND VACUUM GAUGE
    IIt indicates the vacuum or pressure of the sterilisation chamber.
  10. MAIN SWITCH
    Connects or disconnects all the circuits of the autoclave
     
         
     
 

Detail of the bactereological filter and devices for the to drain of the dirty and clean water tanks
      PREVACUUM SYSTEM

The autoclave CLINOCLAV-M is equipped with a device that makes the vacuum in the chamber before the start of the sterilisation process. That makes it possible to achieve a steam saturation inside the chamber for the correct sterilisation. At the same time, once the cycle has finished, there is a vacuum inside the chamber that optimises the drying process.

Due to the vacuum system, the autoclave CLINOCLAV-M is equipped with a bacteriological filter for the air entrance (pourosity 0,2 micras).

PARTICULAR FUNCTIONS

The autoclave CLINOCLAV-M has got level sensors of automatic functioning level, which dosify the necessary water for the sterilisation, or warn if the condensated tank must be refilled, or empties the dirty water tank. The autoclave CLINOCLAV-M always uses clean water for the sterilisation Auto-diagnostical system, which supervises that the sterilisation is done in all its phases. If it doesn’t, the anomaly is shown in the display and it aborts the sterilisation cycle.

Rear connection for the printer RS-232.
     
         
     
          RANGE OF MODELS

     
         
Code Reference Capacity Liters Int. Measures
ØxHeight mm
Ext. Measures mm
(height x width x depth)
Power W Weight Kg
13240011 AH-11 11 200x360 370x510x550 900 40
13250021 AH-21 21 250x415 425x590x680 2000 55
     
   

 

« Autoclaves