- Industrial
- Automatic Paper Testing ( Autoline Profiler )
- Color Measurement Instruments
- Electro Analyzer
- Gas Analyzers
- Industrial Textile Treating Systems
- On-Line Chemical Analyzers
- Package Quality Testing Instruments
- Paper & Board Process Optimization Instruments
- Paper Testing Instruments
- Petroleum Testing Instruments
- Pulp Testing Instruments
- Sieve Shakers / Sieves
- Laboratory
- Amino Acid Analyzers
- Autoclaves
- Balances
- Baths and Circulators
- Bio Reactors / Fermentors
- Blenders
- Block Heaters
- Calibration Equipment
- Calorimeters
- Centrifuges
- Chromatography
- Conductivity Meters
- Deep Freezers / Freezers
- Electrical Test Equipment
- Electronic Test Instruments
- Electrophoresis and Accessories
- Flowmeters
- Fraction Collectors
- Furnaces
- Glassware Washers
- Heating Mantles
- Homogenizers
- Hot Plates
- Incubators
- Ion Meters
- Liyofilization (Freeze Drying) Instruments
- Magnetic Stirrers
- Melting Point Apparatus
- Microplate Readers
- Microscopes
- Mills
- Mixers
- Moisture Analyzers
- Organic Synthesis Systems
- Ovens
- Oxygen Meters
- pH Meters
- Photometers
- Polorimeters
- Presses
- Pressure / Vacuum Meters
- Pumps
- Reactors
- Recorder and Dataloggers
- Refractometers
- Rotary Evaporators
- Salinity Meters
- Sample Preparation Bombs
- Shakers
- Spectrophotometers
- Sterilizers
- Temperature Controlled Heating & Cooling Systems
- Temperature Measuring Instruments
- Thermocycler (PCR)
- Thermohygrometers
- Ultrasonic Cleaners
- Vibration / Leak Detection Instruments
- Viscometers
- Water Purification Systems
- Water Testing Instruments
PARR Series 4560 Mini Bench Top Reactors
PARR Series 4560 Mini Bench Top Reactors
Model 4566 Mini Reactor, Fixed Head, 300 mL, Closed Position
Series 4560 100-600 mL Mini Bench Top Reactors
These are the most popular of all Parr Stirred Reactors. Although they are called “Mini” reactors, they offer a range of sizes large enough to work with significant sample sizes, yet small enough to be handled with ease by all operators. They are made in both fixed head and moveable vessel styles, with a choice of either a self sealing O-ring closure with no cap screws for working temperatures up to 225 °C, or with a flat, PTFE gasket for higher temperatures up to 350 °C sealed with six cap screws in a split- ring cover clamp. Although internal and external space is limited in these small vessels, gas entrainment impellers, catalyst baskets, condensers and other options are available. All reactors in this series can also be easily converted from one size to another by simply substituting a longer or shorter cylinder with the corresponding internal fittings and heaters. The heaters for these vessels are sized to the cylinder dimensions. When converting volumes it is acceptable to use a larger volume cylinder in a smaller heater but not a smaller cylinder in a larger heater. The heaters are designed to be in full contact with the cylinder. An air gap below a smaller vessel will cause the heater to burn-out prematurely. The support system for these Mini Reactors is designed specifically to provide stability at stirring speeds up to 1700 rpm, in a compact mounting small enough to fit into a laboratory hood. The support system can also be adapted to accept any of the smaller vessels from the 4590 Micro Reactor Series.
Model 4563 Mini reactor, 600 mL, Moveable Vessel, Flat Gasket Seal, with Vessel Disassembled, and 4843 Controller
Series 4560 Reactor Specifications
| Shading indicates specifications that change within models |
| Model Number | 4561 | 4562 | 4563 | 4564 | 4565 | 4566 | 4567 | 4568 | 4566B | 4566C |
| Sizes, mL | 300 | 450 | 600 | 160 | 100 | 300 | 450 | 600 | 160 | 100 |
| Maximum Pressure | 3000 psi (200 bar) | |||||||||
| Maximum Temperature | ||||||||||
| with FKM 0-ring | 225 °C | |||||||||
| with FFKM 0-ring | 275 °C | |||||||||
| with PTFE Flat Gasket | 350 °C | |||||||||
| Vessel Style | Removable | Fixed Head | ||||||||
| Reactor Mounting | Bench Top | |||||||||
| Closure (Cap Screws) | Split-Ring (6) | |||||||||
| Valve Connections | 1/8" NPT Male | |||||||||
| Magnetic Stirrer, Model No. | A1120HC6 | |||||||||
| Maximum Torque | 16 Inch-Pounds | |||||||||
| Impeller(s), 4-Blades | 1 | 1 | 2 | 1 | 1 | 1 | 1 | 2 | 1 | 1 |
| Pressure Gage Size | 3.5 inches | |||||||||
| Range | 0-3,000 psi (200 bar)* | |||||||||
| Temperature Measurement | Fixed Thermocouple | |||||||||
| Cooling Coil | Included | Not Included | Included | Not Included | ||||||
| Style | Single Loop | |||||||||
| Bottom Drain Valve, 1/4" | A485VB | |||||||||
| Heater Style | Mantle | Clamp On | Mantle | Clamp On | ||||||
| Heater Power Watts | 400 | 590 | 780 | 500 | 500 | 400 | 590 | 780 | 500 | 500 |
| Stirrer Motor | 1/8 hp variable speed* | |||||||||
| Electrical Supply | ||||||||||
| Volts | 115 or 230 | |||||||||
| Maximum Load, amps, 115/230 | 12/6* | |||||||||
| Vessel Dimensions | ||||||||||
| Inside Diameter, inches | 2.5 | 2.5 | 2.5 | 2.5 | 2 | 2.5 | 2.5 | 2.5 | 2.5 | 2 |
| Inside Depth,inches | 4 | 6 | 8 | 2 | 2 | 4 | 6 | 8 | 2 | 2 |
| Weight of Vessel, pounds | 10 | 13 | 16 | 8 | 9 | 12 | 15 | 18 | 8 | 9 |
| Reactor Dimensions | ||||||||||
| Width, inches w/o Controller | 11.5 | |||||||||
| Depth, inches | 17.5 | |||||||||
| Height, inches | 25.5 | 29.5 | 33.5 | 25.5 | 25.5 | 25.5 | 29.5 | 33.5 | 25.5 | 25.5 |
| Weight, pounds w/Controller | 60 | 63 | 66 | 60 | 60 | 62 | 65 | 68 | 60 | 60 |
| Spare Parts Kit | 4569M | |||||||||
Series 4560 Reactor Ordering Guide
A composite identification number to be used when ordering a mini reactor can be developed by combining individual symbols from the separate sections.Example
A 600 mL, T316SS, reactor with an O-ring gasket, 115 V explosion proof motor, 3000 psi gage and programmable controller with pressure display module would be listed as:
No. 4563-O-SS-115-XP-3000-4843-PDM
|