FTS ULT Series Recirculating Chillers

FTS ULT Series Recirculating Chillers

ULT Series Recirculating Chiller
Ultra-low temperature recirculators provide maximum heat removal to -90°C
Specification Sheet

ULT Series - FTS Systems Wide temperature range from -90°C to +150°C
Cools from 0°C to -80°C in 15 minutes
Mechanically refrigerated, air or water-cooled
Cost-effective heat removal through a constant flow of clean, ultra-low temperature coolant
Applications
  Heat exchangers
  Jacketed vessels
  Plastic molding and extrusion
  Vacuum chambers
  Plasma etch equipment
  Reaction cooling
  Cloud and pour point

Features Benefits
Mechanically refrigerated Eliminates the cost and potential hazards associated with dry ice and liquid nitrogen
Small footprint Saves space
RS-232 interface Remote operation and monitoring of all system functions
Caster-mounted Portability

*Specifications noted below are dependent on fluid choice, fluid temperatures, ambient temperature and electrical supply. Please contact the factory to further discuss your requirements.

Model Specifications
   RC2103 RC2113 RC3111, 3 RC311 GWT1
Heat Removal (watts/BTUs) -20°C 1350/4610 1350/4610 3400/11590 3400/11590
-30°C 1250/4260 1250/4260 3000/10230 3000/10230
-40°C 1150/3925 1150/3925 2700/9207 2700/9207
-50°C 1000/3410 1000/3410 2400/8184 2400/8184
-60°C 880/3005 880/3005 1800/6130 1800/6130
-70°C 550/1877 550/1877 1200/4090 1200/4090
-80°C - - 500/1705  
Temperature Range °C  -80 to -10 -80 to +75 -90 to +75 -75 to +150
Reservoir liters 5 5 5 11.6
Compressor   Two @ 1 hp Two @ 1 hp Two @ 4 hp Two @ 4 hp

Controls

standard: Digital/RS-232 Deluxe Digital Deluxe Digital Deluxe Digital
Control Stability ± °C 0.122 0.12 0.3 0.3
Heater - 1500W 1500W 2500 W
Pump 6 gpm @ 22 PSI 6 gpm @ 22 PSI 6 gpm @ 22 PSI 6 gpm @ 22 PSI
Dimension W x D x H inches 21 x 29 x 48 21 x 29 x 48 21 x 29 x 57 21 x 29 x 57
  cm 53 x 74 x 122 53 x 74 x 122 53 x 74 x 145 53 x 74 x 145
Weight lbs/kg 390/177 390/177 500/227 500/227
Electrical

208-230V
50-60 Hz 18A

208-230V
50-60 Hz 25A

208-230V
50-60 Hz/3ph
21A

208V/ 60 Hz
28A

1. Water-cooled only.
2. Process dependent.
3. 220V/50 Hz also available. Decreases heat removal by 17%.

 

« Temperature Controlled Heating & Cooling Systems