- Industrial
- Automatic Paper Testing ( Autoline Profiler )
- Color Measurement Instruments
- Electro Analyzer
- Gas Analyzers
- Industrial Textile Treating Systems
- On-Line Chemical Analyzers
- Package Quality Testing Instruments
- Paper & Board Process Optimization Instruments
- Paper Testing Instruments
- Petroleum Testing Instruments
- Pulp Testing Instruments
- Sieve Shakers / Sieves
- Laboratory
- Amino Acid Analyzers
- Autoclaves
- Balances
- Baths and Circulators
- Bio Reactors / Fermentors
- Blenders
- Block Heaters
- Calibration Equipment
- Calorimeters
- Centrifuges
- Chromatography
- Conductivity Meters
- Deep Freezers / Freezers
- Electrical Test Equipment
- Electronic Test Instruments
- Electrophoresis and Accessories
- Flowmeters
- Fraction Collectors
- Furnaces
- Glassware Washers
- Heating Mantles
- Homogenizers
- Hot Plates
- Incubators
- Ion Meters
- Liyofilization (Freeze Drying) Instruments
- Magnetic Stirrers
- Melting Point Apparatus
- Microplate Readers
- Microscopes
- Mills
- Mixers
- Moisture Analyzers
- Organic Synthesis Systems
- Ovens
- Oxygen Meters
- pH Meters
- Photometers
- Polorimeters
- Presses
- Pressure / Vacuum Meters
- Pumps
- Reactors
- Recorder and Dataloggers
- Refractometers
- Rotary Evaporators
- Salinity Meters
- Sample Preparation Bombs
- Shakers
- Spectrophotometers
- Sterilizers
- Temperature Controlled Heating & Cooling Systems
- Temperature Measuring Instruments
- Thermocycler (PCR)
- Thermohygrometers
- Ultrasonic Cleaners
- Vibration / Leak Detection Instruments
- Viscometers
- Water Purification Systems
- Water Testing Instruments
Direct-Drive, Rotary Vane Vacuum Pumps
Direct-Drive, Rotary Vane Vacuum Pumps
![]() |
Wide range of free-air capacities to match specific applications |
![]() |
Positive pressure oil system ensures proper lubrication and prevents oil starvation at high gas loads. |
![]() |
Fast acting inlet valve protects internal components against oil and air contamination if the pump stops while under vacuum. |
![]() |
Gas ballast valve limits internal condensation; lets you use pump when condensable vapors are present. |
![]() |
Positive pressure oil system ensures proper lubrication and prevents oil starvation at high gas loads |
![]() |
Fast acting inlet valve protects internal components against oil and air contamination if the pump stops while under vacuum |
![]() |
Gas ballast valve limits internal condensation�use pump when condensable vapors are present |
|
No need to purchase both single- and dual-stage pumps! Dual-mode pumps offer a choice of high-vacuum (HV) mode or high-throughput (HT) mode in one pump. Pumps also feature three-position gas ballast control. Set the pump to HV mode with gas ballast off for use with electron microscopes or mass spectrometers; set it to HT mode with gas ballast fully open for use with gel dryers, vacuum ovens, or rotary evaporators. What�s included: vacuum oil. Pumps do not include a power cord. |
|
| Power cord and plug are included with the pump. | |
| Standard Vacuum Pumps | |
| Use standard pumps for general vacuum applications. Pumps are available in single or dual stage models�use dual-stage pumps to achieve higher vacuum. All standard models include O-ring, centering ring, cable gland, spare seals for oil drain, filter plugs, and vacuum oil (1 liter). Pumps do not include line cord or plug; see page 214 for cord/plug assemblies. Order optional oil mist filter and return kit to reduce maintenance time separately. | |
| Dual-Mode Vacuum Pumps | |
| No need to purchase both single- and dual-stage pumps! Dual-mode pumps offer a choice of high-vacuum (HV) mode or high-throughput (HT) mode in one pump. Pumps also feature three position gas ballast control. Set the pump to HV mode with gas ballast off for uses with electron microscopes or mass spectrometers; set it to HT mode with gas ballast fully open for uses with gel dryers, vacuum ovens, or rotary evaporators. Dual-mode pumps include vacuum oil and 6-ft line cord. To reduce maintenance time, order optional oil mist filter and return kit separately. | |
| Accessories | |
| Service kits include springs, seals, gaskets, O-rings, filters, valves, and washers. Replace every 15,000 hrs. Oil mist filter and return kit directs oil back into your pump reducing oil changes and maintenance time. |
Specifications
| Free air capacity | 2.3 (65) | |
| Max vacuum | without ballast | 1.5 x 10-3 |
| with ballast | 9 x 10-2 | |
| Wetted parts | cast-iron, stainless steel, aluminum, Buna N, flouroelastomers | |
| Max temperature | 104ºF (40ºC) | |
| Motor type | TEFC | |
| Duty cycle | continuous | |
| Noise level | (at 50 Hz) 48 | |
| hp | 1/2 | |
| Amps | 2.6 | |
| VAC/Hz | (115/230)/(50/60) | |
| Inlet port | NW 25 | |
| Outlet port | NW 25 | |
| Oil capacity | 36 (1.1) | |
| Dimensions | 16-7/8 x 6-1/4 x 8-7/8 | |
****To make your own pump system among various number of pump heads, drivers and tubings please contact us. You can choose from Cole-Parmer catalog or if you don't have the catalog you can request from our requests menu in the site.