- Industrial
- Automatic Paper Testing ( Autoline Profiler )
- Climate Chambers
- Crushers / Pulverizers / Dividers
- Electro Analyzer
- Gas Analyzers
- Industrial Textile Treating Systems
- Material Test Chambers
- On-Line Chemical Analyzers
- Package Quality Testing Instruments
- Paper & Board Process Optimization Instruments
- Paper Testing Instruments
- Petroleum Testing Instruments
- Plant Growth Chambers
- Pulp Testing Instruments
- Sieve Shakers / Sieves
- Simulation Chambers
- Laboratory
- Autoclaves
- Balances
- Baths and Circulators
- Bio Reactors / Fermentors
- Blenders
- Block Heaters
- C / H / N - Sulfur Analyzers
- Calibration Equipment
- Calorimeters
- Centrifuges
- Chromatography
- Concentrators / Evaporators
- Conductivity Meters
- Deep Freezers / Freezers
- Electrical Test Equipment
- Electronic Test Instruments
- Electrophoresis and Accessories
- Flowmeters
- Fraction Collectors
- Furnaces
- Glassware Washers
- Heating Mantles
- Homogenizers
- Hot Plates
- Incubators
- Ion Meters
- Liyofilization (Freeze Drying) Instruments
- Magnetic Stirrers
- Mass Spectrometry Systems (GCMS)
- Melting Point Apparatus
- Microplate Readers
- Microscopes
- Mills
- Mixers
- Moisture Analyzers
- Organic Synthesis Systems
- Ovens
- Oxygen Meters
- pH Meters
- Photometers
- Polorimeters
- Presses
- Pressure / Vacuum Meters
- Proximate Analyzer / Ash Fusion Tester
- Pumps
- Reactors
- Recorder and Dataloggers
- Refractometers
- Rotary Evaporators
- Salinity Meters
- Sample Preparation Bombs
- Shakers
- Spectrophotometers
- Sterilizers
- Temperature Controlled Heating & Cooling Systems
- Temperature Measuring Instruments
- Thermocycler (PCR)
- Thermohygrometers
- Ultrasonic Cleaners
- Vibration / Leak Detection Instruments
- Viscometers
- Water Purification Systems
- Water Testing Instruments
BINDER VDL Series Vacuum Drying Ovens (VDL23, VDL53, VDL115)
BINDER VDL Series Vacuum Drying Ovens (VDL23, VDL53, VDL115)
Safety vacuum drying oven for flammable solvents
A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber of the VDL safety vacuum drying oven is designed according to ATEX guidelines for Zone II 3 G.
Advantages:
- Maximum occupational safety with one-of-a-kind safety concept
- Fast, condensation-free drying processes
- Homogeneous specimen drying
Areas of application:
-
Chemicals
-
Surface Technology
-
Pharmaceuticals Industry
Features | Customer benefits | Characteristics |
---|---|---|
APT.line™ |
|
APT.line™ preheating chamber technology
|
Drying |
|
BINDER Cross-Flow Principle
|
Safety concept |
|
Tested security
|
Cleaning |
|
Smooth inner chamber with rounded corners
|
Complete system |
|
Coordinated, modular system
|
Accessories and Services |
|
Comprehensive product portfolio
|
Inner chamber is designed according to ATEX guidelines for Zone II 3G
VDL 23 | ||
---|---|---|
Exterior dimensions | ||
Width (mm) | 515 | |
Height (incl. feet) (mm) | 655 | |
Height with optional vacuum module (mm) | 625 | |
Total Height with optional vacuum module (mm) | 1280 | |
Depth (mm) | 500 | |
Plus door handle, connection (mm) | 100 | |
Wall clearance, rear (mm) | 100 | |
Wall clearance, side (mm) | 135 | |
Interior dimensions | ||
Width (mm) | 285 | |
Height (mm) | 285 | |
Depth (mm) | 295 | |
Interior volume (l) | 23 | |
Expansion racks (aluminum) (number standard/max.) | 2 / 4 | |
Distance between the racks (mm) | 53 | |
Usable space per rack (width x depth) (mm) | 234 x 280 | |
Load per shelf (kg) | 20 | |
Permitted total load (kg) | 35 | |
Weight (empty) (kg) | 63 | |
Temperature data | ||
Temperature range approx. 15 °C above ambient temperature to (°C) | 200 | |
Temperature variation 1) | ||
at 100 °C (± K) | 1,5 | |
at 200 °C (± K) | 3 | |
Temperature fluctuation (± K) 1) | 0,1 | |
Heating up time 1), 2) | ||
to 100 °C (min.) | 65 | |
to 200 °C (min.) | 100 | |
Vacuum data | ||
Vacuum connection with small flange (DN mm) | 16 | |
Measuring access port with small flange (DN mm) | 16 | |
Inert gas connection with flow limiter thread (RP) | 3 / 8 | |
Air pressure connection for pressurized apparatus (tube clip Ø / mm) | 8 | |
Permitted end vacuum (mbar) | 0,01 | |
Leak rate (max. bar 1/h) | 0,01 | |
Electrical data | ||
IP protection class acc. to EN 60529 | IP 54 | |
Voltage (± 10%) 50 / 60 Hz | 230 | |
Nominal power (kW) | 0,8 | |
Energy consumption | ||
at 100 °C (W) | 105 | |
at 200 °C (W) | 280 |
1) Value with aluminum racks
2) To 98% of the set value
VDL 53 | ||
---|---|---|
Exterior dimensions | ||
Width (mm) | 635 | |
Height (incl. feet) (mm) | 775 | |
Height with optional vacuum module (mm) | 625 | |
Total Height with optional vacuum module (mm) | 1400 | |
Depth (mm) | 550 | |
Plus door handle, connection (mm) | 100 | |
Wall clearance, rear (mm) | 100 | |
Wall clearance, side (mm) | 135 | |
Interior dimensions | ||
Width (mm) | 400 | |
Height (mm) | 400 | |
Depth (mm) | 340 | |
Interior volume (l) | 53 | |
Expansion racks (aluminum) (number standard/max.) | 2 / 5 | |
Distance between the racks (mm) | 62 | |
Usable space per rack (width x depth) (mm) | 349 x 320 | |
Load per shelf (kg) | 20 | |
Permitted total load (kg) | 45 | |
Weight (empty) (kg) | 95 | |
Temperature data | ||
Temperature range approx. 15 °C above ambient temperature to (°C) | 200 | |
Temperature variation 1) | ||
at 100 °C (± K) | 2 | |
at 200 °C (± K) | 4,5 | |
Temperature fluctuation (± K) 1) | 0,1 | |
Heating up time 1), 2) | ||
to 100 °C (min.) | 80 | |
to 200 °C (min.) | 115 | |
Vacuum data | ||
Vacuum connection with small flange (DN mm) | 16 | |
Measuring access port with small flange (DN mm) | 16 | |
Inert gas connection with flow limiter thread (RP) | 3 / 8 | |
Air pressure connection for pressurized apparatus (tube clip Ø / mm) | 8 | |
Permitted end vacuum (mbar) | 0,01 | |
Leak rate (max. bar 1/h) | 0,01 | |
Electrical data | ||
IP protection class acc. to EN 60529 | IP 54 | |
Voltage (± 10%) 50 / 60 Hz | 230 | |
Nominal power (kW) | 1,2 | |
Energy consumption | ||
at 100 °C (W) | 150 | |
at 200 °C (W) | 445 |
1) Value with aluminum racks
2) To 98% of the set value
VDL 115 | ||
---|---|---|
Exterior dimensions | ||
Width (mm) | 740 | |
Height (incl. feet) (mm) | 900 | |
Height with optional vacuum module (mm) | 625 | |
Total Height with optional vacuum module (mm) | 1525 | |
Depth (mm) | 670 | |
Plus door handle, connection (mm) | 100 | |
Wall clearance, rear (mm) | 100 | |
Wall clearance, side (mm) | 135 | |
Interior dimensions | ||
Width (mm) | 506 | |
Height (mm) | 506 | |
Depth (mm) | 460 | |
Interior volume (l) | 115 | |
Expansion racks (aluminum) (number standard/max.) | 2 / 6 | |
Distance between the racks (mm) | 68 | |
Usable space per rack (width x depth) (mm) | 455 x 440 | |
Load per shelf (kg) | 20 | |
Permitted total load (kg) | 65 | |
Weight (empty) (kg) | 153 | |
Temperature data | ||
Temperature range approx. 15 °C above ambient temperature to (°C) | 200 | |
Temperature variation 1) | ||
at 100 °C (± K) | 3,5 | |
at 200 °C (± K) | 9 | |
Temperature fluctuation (± K) 1) | 0,1 | |
Heating up time 1), 2) | ||
to 100 °C (min.) | 95 | |
to 200 °C (min.) | 150 | |
Vacuum data | ||
Vacuum connection with small flange (DN mm) | 16 | |
Measuring access port with small flange (DN mm) | 16 | |
Inert gas connection with flow limiter thread (RP) | 3 / 8 | |
Air pressure connection for pressurized apparatus (tube clip Ø / mm) | 8 | |
Permitted end vacuum (mbar) | 0,01 | |
Leak rate (max. bar 1/h) | 0,01 | |
Electrical data | ||
IP protection class acc. to EN 60529 | IP 54 | |
Voltage (± 10%) 50 / 60 Hz | 230 | |
Nominal power (kW) | 1,9 | |
Energy consumption | ||
at 100 °C (W) | 250 | |
at 200 °C (W) | 785 |
1) Value with aluminum racks
2) To 98% of the set value
OPTIONS | |
---|---|
ATEX connection kit VP 4, consists of: clamping rings, aluminum universal centering ring, transition piece adapter, anti-static vacuum hose, union nut, elbow | O |
ATEX connection kit VP 5, consists of: clamping rings, aluminum, universal centering ring, outer centering ring, transition piece adapter, union nut, anti-static vacuum hose, elbow | O |
Measuring port. For vacuum-tight access port of measuring lines into the device (9-pin) | O |
Temperature measurement of the specimen via flexible PT 100 sensor (EX-proof via measurement current access port) and digital temperature display | O |
Factory calibration certificate, measurement in center of chamber at 100 °C or at specified testing temperature | O |
Extension to factory calibration certificate. Each additional measurement at additional measuring point or testing temperature | O |
VP 4 chemical membrane pump (nominal air flow 1.9 m³/hour, final pressure 12 mbar), with separator and emission condenser 230 V 1N ~ 50 Hz | O |
Expansion racks, aluminum | O |
Expansion racks, stainless steel | O |
Exchange and calibration to stainless steel expansion racks, standard equipment aluminum expansion racks are replaced | O |
Door gasket, FKM (Viton) | O |
Vacuum module (empty) for installation of vacuum pumps | O |
Vacuum module with membrane pump VP 4, mechanical and electrical membrane pump components EX-proof, ATEX approved (nominal air flow 1.9 m³ / hour, final pressure 12 mbar), with separator and emission condenser, including all necessary vacuum connection parts | O |