BINDER VD Series Vacuum Drying Ovens (VD23, VD53, VD115)

BINDER VD Series Vacuum Drying Ovens (VD23, VD53, VD115)

 

Vacuum drying oven for non-flammable solvents

A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution. The patented expansion shelf technology from BINDER ensures optimal heat transfer. The shelves are easy to position where required and the inner chamber of the vacuum drying oven is easy to clean.

Advantages:
  • Maximum occupational safety with one-of-a-kind safety concept
  • Fast, condensation-free drying processes
  • Homogeneous specimen drying

 

Areas of application:
  • Electronics / Semiconductor Industry
  • Plastics Industry
  • Pharmaceuticals Industry
FeaturesCustomer benefitsCharacteristics
APT.line™
  • Gentle drying throughout the chamber interior
  • Absolute temperature uniformity
  • Direct transfer of heat to the specimens
  • Reproducible drying results

APT.line™ preheating chamber technology

  • Thermal conducting plates for homogeneous temperature distribution
  • Condensation-free inner chamber
  • Patented, flexible positioning of the expansion racks with large contact surfaces
Drying
  • Fast drying thanks to accelerated drying process
  • Light specimens (e.g. powder) are not swirled

BINDER Cross-Flow Principle

  • Even flow throughout the inner chamber from bottom to top
  • Finely adjustable valve without turbulence, individually controlled
Safety concept
  • Maximum occupational safety with recognized safety concept
  • Protection for user and laboratory

Tested security

  • Spring-mounted safety glass panel with shatter protection (FDA tested)
  • Standard interior flushing with inert gas
  • Electronic components are decoupled from the inner chamber
Cleaning
  • Simple, time-saving cleaning
  • Durable materials

Smooth inner chamber with rounded corners

  • Fixtures are fully removable
  • Inner chamber made of highly corrosion resistant stainless steel V4A (1.4571)
Complete system
  • Everything from one source
  • Optimal working height
  • 50% less noise
  • Pressure and temperature profiles are depicted simultaneously

Coordinated, modular system

  • Contains vacuum drying chamber, vacuum pumps, module and connection kit for various sizes
  • Application-specific vacuum pumps (standard membrane pump, speed-controlled membrane pump)
Accessories and Services
  • Convenient documentation and validation
  • BINDER INDIVIDUAL for customer-specific solutions
  • Worldwide BINDER Service

Comprehensive product portfolio

  • Years of proven and recognized validation and documentation materials
  • Various options: Digital pressure indicator, object temperature indicator
  • Vacuum pump and chamber controllable using FDA-compliant software APT-COM™
  • Worldwide service network

Electronically controlled APT.line™ preheating chamber with 2 expansion racks assuring temperature accuracy and reproducible results

  • Temperature range from 15 °C above ambient temperature to 200 °C
  • MP controller with 2 programs with 10 sections each or switchable to 1 program with 20 sections
  • Integrated weekly program timer with real-time function
  • Digital temperature setting with an accuracy of one degree
  • Elapsed time indicator
  • Precision-adjustable ventilation valve (for VD 23, the standard inert gas connection is also used as the ventilation valve)
  • Precision-adjustable inert gas valve with Cross-Flow-Technology
  • All electrical components are decoupled from the inner chamber
  • Spring-mounted safety glass panel with shatter protection
  • Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
  • Measuring port DN 16 in rear panel
  • Analog pressure gauge (displays pressure difference between the inner chamber and ambient pressure)
  • Electro polished inner chamber, suction and ventilation tubes, pressure container, expansion racks, and ball valve are made of stainless steel
  • Door gasket made of tempered silicone
  • 2 x 24 V DC (max 0.4 A) switching outputs, switched via 2 control contacts in the program editor
  • RS 422 interface for communication software APT-COM™ DataControlSystem
  • 2 patented, flexible aluminum expansion racks
  • Also available as complete system with module and vacuum pump. Features:
  • Reduced noise level
  • Practical working height
  • Coordinated system
  • BINDER test confirmation
  •  

    VD 23

     

     

     

    Exterior dimensions  
      Width (mm) 515
      Height (incl. feet) (mm) 655
      Height with optional vacuum module (mm) 625
      Height with optional vacuum module (mm) 1280
      Depth (mm) 500
      Plus door handle, connection (mm) 100
      Wall clearance, rear (mm) 100
      Wall clearance, side (mm) 135
         
      Interior dimensions  
      Width (mm) 285
      Height (mm) 285
      Depth (mm) 295
      Interior volume (l) 23
      Expansion racks (aluminum) (number standard/max.) 2 / 4
      Distance between the racks (mm) 53
      Usable space per rack (width x depth) (mm) 234 x 280
      Load per shelf (kg) 20
      Permitted total load (kg) 35
      Weight (empty) (kg) 63
         
      Temperature range  
      Temperature range approx. 15 °C above ambient temperature to (°C) 200
      Temperature variation 1)  
      100 °C (± K) 1,5
      200 °C (± K) 3
      Temperature fluctuation (± K) 1) 0,1
      Heating up time 1), 2)  
      to 100 °C (min.) 65
      to 200 °C (min.) 100
      Vacuum connection with small flange (DN mm) 16
      Measuring access port with small flange (DN mm) 16
      Inert gas connection with flow limiter thread (RP) 3 / 8
      Permitted end vacuum (mbar) 0,01
      Leak rate (max. bar 1/h) 0,01
         
      Electrical data  
      IP protection class acc. to EN 60529 IP 20
      Voltage (± 10%) 50 / 60 Hz 230
      Nominal power (kW) 0,8
      Energy consumption  
      at 100 °C (W) 105
      at 200 °C (W) 280

    1) Value with aluminum racks
    2) To 98% of the set value

     

    VD 53
      Exterior dimensions  
      Width (mm) 635
      Height (incl. feet) (mm) 775
      Height with optional vacuum module (mm) 625
      Height with optional vacuum module (mm) 1400
      Depth (mm) 550
      Plus door handle, connection (mm) 100
      Wall clearance, rear (mm) 100
      Wall clearance, side (mm) 135
         
      Interior dimensions  
      Width (mm) 400
      Height (mm) 400
      Depth (mm) 340
      Interior volume (l) 53
      Expansion racks (aluminum) (number standard/max.) 2 / 5
      Distance between the racks (mm) 62
      Usable space per rack (width x depth) (mm) 349 x 320
      Load per shelf (kg) 20
      Permitted total load (kg) 45
      Weight (empty) (kg) 95
         
      Temperature range  
      Temperature range approx. 15 °C above ambient temperature to (°C) 200
      Temperature variation 1)  
      100 °C (± K) 2
      200 °C (± K) 4,5
      Temperature fluctuation (± K) 1) 0,1
      Warm-up time 1), 2)  
      to 100 °C (min.) 80
      to 200 °C (min.) 115
      Vacuum connection with small flange (DN mm) 16
      Measuring access port with small flange (DN mm) 16
      Inert gas connection with flow limiter thread (RP) 3 / 8
      Permitted end vacuum (mbar) 0,01
      Leak rate (max. bar 1/h) 0,01
         
      Electrical data  
      IP protection class acc. to EN 60529 IP 20
      Voltage (± 10%) 50 / 60 Hz 230
      Nominal power (kW) 1,2
      Energy consumption  
      at 100 °C (W) 150
      at 200 °C (W) 445

    1) Value with aluminum racks
    2) To 98% of the set value

    VD 115
      Exterior dimensions  
      Width (mm) 740
      Height (incl. feet) (mm) 900
      Height with optional vacuum module (mm) 625
      Height with optional vacuum module (mm) 1525
      Depth (mm) 670
      Plus door handle, connection (mm) 100
      Wall clearance, rear (mm) 100
      Wall clearance, side (mm) 135
         
      Interior dimensions  
      Width (mm) 506
      Height (mm) 506
      Depth (mm) 460
      Interior volume (l) 115
      Expansion racks (aluminum) (number standard/max.) 2 / 6
      Distance between the racks (mm) 68
      Usable space per rack (width x depth) (mm) 455 x 440
      Load per shelf (kg) 20
      Permitted total load (kg) 65
      Weight (empty) (kg) 153
         
      Temperature range  
      Temperature range approx. 15 °C above ambient temperature to (°C) 200
      Temperature variation 1)  
      at 100 °C (± K) 3,5
      at 200 °C (± K) 9
      Temperature fluctuation (± K) 1) 0,1
      Heating up time 1), 2)  
      to 100 °C (min.) 95
      to 200 °C (min.) 150
      Vacuum connection with small flange (DN mm) 16
      Measuring access port with small flange (DN mm) 16
      Inert gas connection with flow limiter thread (RP) 3/8
      Permitted end vacuum (mbar) 0,01
      Leak rate (max. bar 1/h) 0,01
         
      Electrical data  
      IP protection class acc. to EN 60529 IP 20
      Voltage (± 10%) 50 / 60 Hz 230
      Nominal power (kW) 1,9
      Energy consumption  
      at 100 °C (W) 250
      at 200 °C (W) 785

    1) Value with aluminum racks
    2) To 98% of the set value

     

    OPTIONS
    Connection kit consists of: clamping ring, aluminum, centering ring, small flange with hose nozzle, (2.5 m) rubber hose and 2 hose clamps. O
    Measuring port. For vacuum-tight access port of measuring lines into the device (9-pin) O
    Factory calibration certificate, measurement in center of chamber at 100 °C or at specified testing temperature O
    Extension to factory calibration certificate. Each additional measurement at additional measuring point or testing temperature O
    Factory calibration certificate for digital pressure gauge. Measurement at 100 mbar or at specified test pressure (range 20-900 mbar) O
    Extension to factory calibration certificate for digital pressure gauge. Each additional measurement with additional test pressure (range 20-900 mbar) O
    Temperature measurement of the specimen with flexible PT 100 O
    Factory calibration certificate for digital specimen temperature display. O
    VP 1.1 chemical membrane pump (nominal air flow 2.0 m³/hour, final pressure 7 mbar), with separator and emission condenser (230 V 1N ~ 50 / 60 Hz) O
    VP 2.1 chemical membrane pump (nominal air flow 3.4 m³/hour, final pressure 7 mbar), with separator and emission condenser (230 V 1N ~ 50 / 60 Hz) O
    VP 3.1 speed-controlled chemical membrane pump (nominal air flow 4.6 m³/hour, final pressure 1.5 mbar), with separator and emission condenser (230 V 1N ~ 50 / 60 Hz) O
    Expansion racks, aluminum O
    Expansion racks, stainless steel O
    Exchange and calibration to stainless steel expansion racks, standard equipment aluminum expansion racks are replaced O
    Door gasket, FKM (Viton) O
    Digital pressure display, measuring range from 1 mbar to atm. pressure, display accuracy 1 mbar O
    Vacuum module for installation of vacuum pumps, with switchable power socket (ON/OFF) (230 V / 16 A) O
    Vacuum module with chemical membrane pump VP 1.1 (nominal air flow 2.0 m³/hour, final pressure 7 mbar), with separator and emission condenser, including all necessary vacuum connection parts 230 V 1N ~ 50 / 60 Hz O
    Vacuum module with chemical membrane pump VP 2.1 (nominal air flow 3.4 m³/hour, final pressure 7 mbar), with separator and emission condenser, including all necessary vacuum connection parts 230 V 1N ~ 50 / 60 Hz O
    Vacuum module with speed-controlled chemical membrane pump VP 3.1 (nominal air flow 4.6 m³/hour, final pressure 1.5 mbar), with separator and emission condenser, including all necessary vacuum connection parts, as well as digital vacuum controller (measuring precision ≤1 mbar) 230 V 1N ~ 50 / 60 Hz O