- Industrial
- Automatic Paper Testing ( Autoline Profiler )
- Climate Chambers
- Crushers / Pulverizers / Dividers
- Electro Analyzer
- Gas Analyzers
- Industrial Textile Treating Systems
- Material Test Chambers
- On-Line Chemical Analyzers
- Package Quality Testing Instruments
- Paper & Board Process Optimization Instruments
- Paper Testing Instruments
- Petroleum Testing Instruments
- Plant Growth Chambers
- Pulp Testing Instruments
- Sieve Shakers / Sieves
- Simulation Chambers
- Laboratory
- Autoclaves
- Balances
- Baths and Circulators
- Bio Reactors / Fermentors
- Blenders
- Block Heaters
- C / H / N - Sulfur Analyzers
- Calibration Equipment
- Calorimeters
- Centrifuges
- Chromatography
- Concentrators / Evaporators
- Conductivity Meters
- Deep Freezers / Freezers
- Electrical Test Equipment
- Electronic Test Instruments
- Electrophoresis and Accessories
- Flowmeters
- Fraction Collectors
- Furnaces
- Glassware Washers
- Heating Mantles
- Homogenizers
- Hot Plates
- Incubators
- Ion Meters
- Liyofilization (Freeze Drying) Instruments
- Magnetic Stirrers
- Mass Spectrometry Systems (GCMS)
- Melting Point Apparatus
- Microplate Readers
- Microscopes
- Mills
- Mixers
- Moisture Analyzers
- Organic Synthesis Systems
- Ovens
- Oxygen Meters
- pH Meters
- Photometers
- Polorimeters
- Presses
- Pressure / Vacuum Meters
- Proximate Analyzer / Ash Fusion Tester
- Pumps
- Reactors
- Recorder and Dataloggers
- Refractometers
- Rotary Evaporators
- Salinity Meters
- Sample Preparation Bombs
- Shakers
- Spectrophotometers
- Sterilizers
- Temperature Controlled Heating & Cooling Systems
- Temperature Measuring Instruments
- Thermocycler (PCR)
- Thermohygrometers
- Ultrasonic Cleaners
- Vibration / Leak Detection Instruments
- Viscometers
- Water Purification Systems
- Water Testing Instruments
BINDER CB150 CO2 Incubator
BINDER CB150 CO2 Incubator
CO2 incubator with additional process controls
The BINDER CB series CO2 incubator is the premium class among the CO2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CO2 incubator of the CB series is up to even complex cultivation experiments or individual environments.
Advantages:
- Hot air sterilization at 180 °C
- Seamless, deep-drawn inner chamber made of stainless steel
- Unique BINDER technology (patented air jacket system, controlled condensation, etc.)
Areas of application:
-
Bio Tissue Engineering
-
In vitro Fertilization (IVF)
-
Clinics / University Hospitals
Features | Customer benefits | Characteristics |
---|---|---|
Sterilization |
|
180 °C hot air sterilization
|
Permadry™ humidity system |
|
Controlled humidification system
|
APT.line™ heating technology |
|
Preheating chamber with VENTAIR™ air jacket
|
Gas distribution |
|
Gas mixing head with venturi effect
|
Inner chamber concept |
|
Seamless, deep-drawn inner chamber
|
CO2 measurement |
|
Single-beam infrared sensor
|
Operating costs |
|
|
Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and best cell growth
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real time clock
CB 53 | ||
---|---|---|
Exterior dimensions | ||
Width (mm) | 580 | |
Height (incl. feet) (mm) | 720 | |
Depth (plus 55 mm for door handle and connection) (mm) | 550 | |
Wall clearance side / rear (mm) | 50 / 100 | |
Number of doors (ea.) | 1 | |
Inner glass door(s) | 1 | |
Interior dimensions | ||
Width (mm) | 400 | |
Height (mm) | 400 | |
Depth (mm) | 330 | |
Interior volume (l) | 53 | |
Number of shelves (standard/max.) | 2 / 3 | |
Dimensions shelves width x depth (mm) | 396 x 289 | |
Load per shelf (kg) | 10 | |
Permitted total load (kg) | 30 | |
Weight (empty) (kg) | 60 | |
Temperature data | ||
Temperature range from 5 °C above ambient temperature to (°C) | 60 | |
Temperature variation at 37 °C (± K) | 0,3 | |
Temperature fluctuation at 37 °C (± K) | 0,1 | |
Recovery time after door was opened for 30 sec. at 37 °C (min.) 1) | 3 | |
Humidity data | ||
Humidity (±2% r.h.) | 95 | |
CO2 data | ||
CO2 range (vol. % CO2) | 0 - 20 | |
Setting accuracy (Vol.-% CO2) | 0,1 | |
Recovery time after door was opened for 30 sec. 1) | ||
at 5.0 vol. % CO2 (min.) | 6 | |
CO2 measurement | IR | |
Connection hose nozzle for CO2 for hose with internal diameter (mm) | 6 | |
O2 data | ||
O2 range (vol. % O2) | 0,2 - 95 | |
Setting accuracy (Vol.-% O2) | 0,1 | |
Recovery time after door was opened for 30 sec. 1) | ||
at 1.0 vol. % O2 (min.) | 25 | |
at 5.0 vol. % O2 (min.) | 9 | |
O2 measurement | ZrO2 | |
Connection hose nozzle for O2 / N2 for hose with internal diameter (mm) | 6 | |
Electrical data | ||
Voltage (± 10%) 50/60 Hz (V) | 230 | |
Nominal power (kW) | 1,0 | |
Energy consumption at 37 °C (W) 2) | 70 |
1) up to 98 % of the set value
2) These values can be used for dimensioning air condition systems.
OPTIONS |
|
---|---|
Silicone access port with two silicone plugs, 30 mm, back | O |
Lockable controller keyboard | O |
Gas tank connection set for CO2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose | O |
Gas tank connection set for O2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose | O |
Gas tank connection set for N2 consisting of a gas tank pressure regulator max. pressure 10 bar) with connection parts and 5 m hose | O |
BINDER Gas Supply Service external gas tank replacement for connecting 2 gas tanks, either CO2 or N2, with audible and visual alarms, as well as potential-free alarm output | O |
Unit conversion from RS 422 to Ethernet interface | O |
4 - 20 mA analog outputs for temperature and CO2 measurements (e.g. chart recorder connection) with 6-pin DIN socket (output not adjustable) | O |
Switched LEMO inner chamber socket (coverable) and LEMO connector (max. current carrying capacity 230 V AC - 3 A) (protection class IP 65) | O |
Independent Intelligent Fail Safe monitoring function. Unique safety function used to prevent unnoticed deviations of the CO2 concentration from the set value. Note: Not possible in conjunction with access ports or divided inner glass door | O |
Calibration certificate for temperature and CO2 (temperature measurement in center / CO2 measurement performed using analyzed test gas at 37 °C and 5% CO2) | O |
Calibration certificate for optional O2 control, O2 measurement with analyzed test gas 1% O2 | O |
Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C or at specified temperature with measuring protocol and certificate | O |
Manual for Primary Human Cell Culture, in English | O |
Shelf, perforated, stainless steel | O |
Shelf, stainless steel for divided gas-tight inner glass door | O |
Base on casters | O |
Stacking adapter for direct thermal decoupled stacking of two C 53 CO2 incubators | O |